TM 11-6625-828-45
c. Procedure.
Step
Control settings
No.
Test Equipment
Equipment under test
Test procedure
Performance standard
1
a. MODULATION switch to 30-.
a. Adjust test set 30- MOD control
a
None.
ME-SOE/U:
RANGE: 30 mv.
IDENTIFIER switch to OFF.
for green line indication on %M
F12 FILTER: 30~.
meter. Adjust DEMOD output
with screwdriver for 0.03 volt
indication on ME-30E/U.
b. MODULATION switch to 90O.
b. Adjust test set 90- MOD control
b.
None.
for redline indication on %M
meter.
c. . MODULATION switch to 150-.
c. Adjust test set 1590 MOD control
c.
None.
for redline indication on %M
meter.
2
F12 FILTER: 90-.
MODULATION switch to AMP LOC
Measure voltage with ME-30E/U.
Between 0.019 and 0.021 volt.
3
F12 FILTER: 150-.
Measure voltage with ME-30E/U.
Between 0.019 and 0.021 volt.
4
F12 FILTER: 90-.
Adjust test set DEMOD control with
None.
screwdriver for 0.020 volt indication
None.
on ME40E/U.
5
F12 FILTER: 90-.
MODULATION switch to AMP LOC
Measure voltage on MECOE/U.
Between 0. 0149 and 0.0168 volt.
6
F12 FILTER: 150--.
Measure voltage on ME-30E/U.
Between 0.0237 and 0.0267 volt.
7
F12 FILTER: 90--
MODULATION switch to AMP LOC
Measure voltage on ME-30E/U.
Between 0.0237 and 0.0267 volt.
8
P12 FILTER: 150-.
Measure voltage on ME-30E/U.
Between 0.0149 and 0.0168 volt.
4-16