TM 11-6625-2709-40
2-8.
Troubleshooting
Chart
-
Continued
Probable trouble
Proper
for improper
Correction
Procedure
Step
indication
indication
c. Troubleshoot the con-
c. If 0.01 FREQ SELECT
11
trol unit as described
(MHz) lamp B does not
(Cont)
in TM 11-5826-226-34.
light, the kilohertz se-
is defective.
Troubleshoot the control
The kilohertz selector in
Set the megahertz
0.1 FREQ SELECT
unit as described in TM
and kilohertz se-
(MHz) lamps B and
11-5826-226-34.
defective.
lectors to 108.45.
D should light.
Same as step 12 above.
Same as step 12 above.
0.1 FREQ SELECT
Set the megahertz
and kilohertz se-
(MHz) lamps C and
lectors to 108.50.
D should light. 0.01
FREQ SELECT
(MHz) lamp B should
light. GS/LOC ON
lamp should light.
Same as step 12 above.
Same as step 12 above.
Set the megahertz
0.1 FREQ SELECT
and kilohertz se-
(MHz) lamps C and
lectors to 108.55.
D should light.
Same as step 12 above.
Same as step 12 above.
Set the megahertz
0.1 FREQ SELECT
(MHz) lamps C and
and kilohertz se-
lectors to 108.60.
E should light. 0.01
FREQ SELECT
(MHz) lamp B should
light.
Same as step 12 above.
Same as step 12 above.
16
0.1 FREQ SELECT
Set the megahertz
and kilohertz se-
(MHz) lamps C and
lectors to 108.65.
E should light.
Same as step 12 above.
17
Same as step 12 above.
Set the megahertz
0.1 FREQ SELECT (MHz)
and kilohertz se-
lamps D and E should
light. 0.01 FREQ
lectors to 108.70.
SELECT (MHz) lamp B
should light. GS/LOC
ON lamp should light.
18
Same as step 12 above.
Set the megahertz
0.1 FREQ SELECT (MHz)
Same as step 12 above.
lamps D and E should
and kilohertz se-
light. GS/LOC ON
lectors to 108.75.
lamp should light.
19
Same as step 12 above.
0.1 FREQ SELECT (MHz)
Set the megahertz
Same as step 12 above.
lamps A and D should
and kilohertz se-
light. 0.01 FREQ
lectors to 108.80.
SELECT (MHz) lamp B
should light.
Set the megahertz
Same as step 12 above.
Same as step 12 above.
20
0.1 FREQ SELECT
and kilohertz se-
(MHz) lamps A and
lectors to 108.85.
D should light.
21
Set the megahertz
Same as step 12 above.
0.1 FREQ SELECT
Same as step 12 above.
and kilohertz se-
(MHz) lamps A and
E should light. 0.01
lectors to 108.90.
FREQ SELECT
(MHz) lamp B should
light. GS/LOC ON
lamp should light.
2-19
Change 1