TM 11-6625-2709-40
Troubleshooting Chart-Continued
Probable trouble
Proper
for improper
Correction
Procedure
Step
indication
indication
f. If a break in the circuit
f. If 1.0 FREQ SELECT
f. 1.0 FREQ SELECT
2 (Cont)
is present, make resis-
(MHz) lamp A does not
(MHz) lamp A on
tance measurements to
light, either a break in
aid box.
find the break. If no
the circuit is present
break is present,
between P2-W and
troubleshoot the con-
P5-V, or the megahertz
trol unit as described
selector in the control
in TM 11-5826-226-34.
unit is defective.
g. If a break in the circuit
g. If 1.0 FREQ SELECT
g. 1.0 FREQ SELECT
is present, make resis-
(MHz) lamp D does not
(MHz) lamp D on
tance measurements to
light, either a break in
aid box.
find the break. If no
the circuit is present
break is present,
between P2-T and
troubleshoot the con-
P5-F, or the megahertz
trol unit as described
selector in the control
in TM 11-5826-226-34.
unit is defective.
h. If a break in the circuit
h. If 0.1 FREQ SELECT
h. 0.1 FREQ SELECT
is present, make resis-
(MHz) lamp B does not
(MHz) lamp B on
tance measurements to
light, either a break in
aid box.
find the break. If no
the circuit is present
break is present,
between P2-g and
troubleshoot the con-
P5-D, or the kilohertz
trol unit as described
selector in the control
unit is defective.
TM 11-5826-226-34.
i. If a break in the circuit
i. If 0.1 FREQ SELECT
i. 0.1 FREQ SELECT
is present, make resis-
(MHz) lamp E does not
(MHz) lamp E on
tance measurements to
light, either a break in
aid box.
find the break. If no
the circuit is present
break is present,
between P2-j and P5-B,
troubleshoot the con-
or the kilohertz se-
trol unit as described
lector in the control
in TM 11-5826-226-34.
unit is defective.
j. If a break in the circuit
j. If 0.01 FREQ SELECT
j. 0.01 FREQ SE-
is present, make resis-
LECT (MHz) lamp
(MHz) lamp B does not
tance measurements to
light, either a break in
B on aid box.
find the break. If no
the circuit is present
break is present,
between P2-p and
troubleshoot the con-
P5-g, or the kilohertz
selector in the control
trol unit as described
in TM 11-5826-226-34.
unit is defective.
k.
k.
k. FLAG meter
If FLAG meter does not
should indicate
indicate 250 15.0
on the circuit com-
250 15.0 micro-
microamperes, switch S6
prised of S6 and M2 to
ampere.
or FLAG meter M2 is
isolate the trouble.
defective.
l. DEVIATION meter
l. If DEVIATION meter
should indicate
does not indicate
75 10 micro-
75 10 microamperes
on the circuit com-
amperes to the
to the right of 0,
prised of S6 and M1 to
right of 0.
switch S6 or DEVIATION
isolate the trouble.
meter M1 is defective.
(Cont)
Change 1