TM 11-6625-828-45
Control settings
Test equipment
Equipment under test
Test procedure
Performance standard
1
TSO:52B/U:
POWER-STANDBY switch:
a. Measure output of CN-16A/U
a. None
a. FUNCTION: AC volts.
POWER.
with TS-352B/U and adjust
RANGE: 250 volts
voltage to 115 volts.
CN-16A/U voltage
b. Measure dc voltage at pin 3 of
control to 115 volts.
V114.
b. Between 390 and 420 volts dc.
b. FUNCTION: DC volts.
c. Set output of CN-16A/U to 100
RANGE: 500 volts.
volts.
c.
None.
c. FUNCTION: AC volts
CN-16A/U voltage
d
Measure dc voltage at pin 3 of
control to 100 volts
V114.
d. Value obtained in b above +2
d. FUNCTION: DC volts
e. Set output of CN-16A/U to 130
volts.
RANGE: 250 volts
RANGE: 500 volts
volts.
e. None.
e. FUNCTION: AC volts
CN-16A/U voltage
f.
Measure dc voltage at pin 3 of
control to 130 volts
V114.
f.
Value obtained in b above +2
f. FUNCTION: DC volts
g. Repeat a above.
volts.
RANGE: 250 volts
RANGE: 500 volts
h. Measure voltage at positive end of
g. None.
g. Repeat a above.
C160 (orange wire).
h. Between 245 and 273 volts.
RANGE: 500 volts
C161 (pink wire).
i Between 185 and 215 volts.
A. FUNCTION: DC volts
i
Measure voltage at positive end of
RANGE: 250 volts
sleeve of standard 3-conductor
j.
Between 1.45 and 1.7 ma.
i
FUNCTION: DC volts
j. Measure current between ring and
j. FUNCTION: DC cur-
jack plug inserted into the test
rent
set MIC jack.
RANGE: 5 ma
4-8