TM 11-5895-1096-40
Table 3-7 TS-3566/GRA-l14 Physical Tests and Inspection -
Cont.
Step
Control Settings
No
Test Equipment
Unit under test
Test Procedures
Performance Standard
c. Inspect painted surfaces for scratches and c. All painted surfaces shall be free of scrat-
cracked or peeling paint.
ches Which penetrate the paint, and
cracked or peeling paint.
d. Inspect screws. nuts and bolts for loose- d. All screws, bolts and nuts shall be tight;
ness.
none shall be missing
e. Inspect front panel switches for loose-
e. Switch knobs shall be tight and mechani-
ness, missing knobs and normal switch
cal action normal.
action.
f. Inspect front panel indicator for burned-
f. Indicator bulb shall be installed and in
out or missing bulb.
working order.
g. Fuse shall be correct size (A), installed
size, burned out, or missing fuse.
and in working order.
h. Inspect electrical components and print- h. Electrical components and printed circuit
ed circuit cards for signs of heat damage. cards shall be free of heat damage.
I. Inspect electrical components and printed i Electrical components and printed circuit
circuit cards for signs of physical damage cards shall be free of physical damage.
j. Inspect wiring for breaks and damaged or j. All siring shall be free of damage to Insu-
frayed insulation.
lation and conductors.
3-23. TS-35661GRA-114 Performance Test
a. Test Equipment and Materials
a. Test Equipment and Materials.
(1) Dual Time Base TD-1159/U
(1) BNC/UHF Adapter UG-273/U.
(2) Dual Trace Amplifier AM-6880/L
(2) Dual Time Base TD-1159/U.
(3) Maintenance Kit MK-1752/GRA-1 14
(3) Dual Trace Amplifier AM6880/U.
(4) Maintenance Kit MK-1752/GRA-114.
b. Test Connectors and Conditions. Connect equip-
(6) Probe P6105, 2 meters long.
b. Test Connections and Conditions. Connect equip-
3-24. 19.25 MHz Amplifier
Performance Test
3-22