Section III. TROUBLESHOOTING
5-5. General Instructions
5-6. Interconnecting Box Troubleshooting
Table 5-3 is a
troubleshooting chart for the
intercon-
This section contains troubleshooting information for
each component of the test set group. Continuity checks
netting box. This procedure will check all the internal
and a trouble analysis flow diagram are provided to
wiring, functioning of the controls and indicators, and
supplement maintenance procedures.
operation of the relay, K1.
Table 5-3. Troubleshooting Chart for Interconnecting Box
Control setting
Equipment
Test
Step
Performance standard
Test procedures
under test
no.
equipment
1
All Switches OFF
All meas-
tween the following
unless otherwise
urements
points (follow con-
specified.
made with
trol settings and
performance standards
set on
listed):
OHMS and
TO
FROM
RX100.
Continuity
J4M
J5A
CB1 DC ON
No continuity
J4M
J5A
CB2 AC OFF
Continuity
J4K
J5D
S5 ON
No continuity
J4K
J5D
S5 OFF
Continuity
J4E
J5D
S3 XMT KEY
100 to 200 ohms
J4E
J5D
S3 OFF
Continuity
J4E
J5D
S3 MOM ON
Continuity
J2R
J5D
S6-30 WATT