Performance standard
Test procedures
Equipment under test
Test equipment
step
control settings
control settings
No.
OPERATE lamp 11 lights.
None.
Set POWER-OFF switch S7 to
Controls in any position.
1.
POWER.
Model 8100 indicates 27.0 0.5 Vdc.
Observe Model 8100.
POWER-OFF switch S7; in POWER.
VDC:
2.
Depressed
RANGE: 100
Insert test cable connector P1 into
a. SELF TEST lamp 12 lights.
None.
Same as step 2.
3.
b. OPERATE lamp 11 goes out.
SELF TEST RECEPTACLE J8.
RECEIVER SEL switch S4: OFF;
Hold KEYING switch S1 to RADIO
KEY ON lamp 13 lights when
None.
4.
KEYING switch S1 is in RADIO
and then to INTER.
and INTER positions, and goes
1; INPUT SEL switch S3: R;
Signal switch: METER.
out in midposition.
RECEIVER SEL switch S4: OFF;
a. Hold KEYING switch S1 to
a. Same as step 4.
None.
5.
METER;
switch:
SIGNAL
RADIO and then to INTER for
each setting of TRANSMITTER
2; INPUT SEL switch S3: R.
SEL switch S5.
b. Same as step 4.
b. Repeat step a with TRANS-
MITTER SEL switch S5 in
positions 3, 4, and ALTN.
Test Set, Radio TS-1588/AIC
KEY ON lamp 13 shall light when
None.
Hold SIGNAL switch S6 to HD MIC
6.
SIGNAL switch S6 is in HD MIC
and release.
4. Test Set, Radio TS- 1588 A/AIC
and go out when releasd.
A L T N; other switches same as
l
step 5.
Same as step 6.
None.
Same as step 6 except OUTPUT SEL
Same as step 6.
7.
switch S2: 1.
Same as step 6.
OUTPUT SEL switch S2: T. Test
None.
Same as step 6.
8.
Set, Radio TS-1588/AIC TRANS-
MITTER SEL switch S5: 3, 2,
and 1. Test Set, Radio TS-
1588A/AIC TRANSMITTER SEL
switch S5, 4, 3, 2, end 1.
a. Rotate Test Set, Radio TS-
None.
a. KEY ON lamp 13 shall light for
9.
1588/AIC RECEIVER SEL
each RECEIVER SEL switch S4
switch S4 from 1 through IN-
position.
TER.
b. Rotate Test Set, Radio TS-
b. Same as a. above.
1588A/AIC RECEIVER SEL
switch S4 from 1 through EMER.
KEY ON lamp 13 lights with INPUT
RECEIVER SEL switch S4: OFF. Rotate INPUT SEL switch S3 to I
10.
None.
TRANSMITTER SEL switch S5 to
and then T.
SEL switch S3 in I and does not
light in T.
1. OUTPUT SEL switch S2 to R.
None.
Remove test cable connector P1 from
Controls in any position.
SELF TEST lamp 12 goes out and
11.
SELF TEST RECEPTACLE J8,
OPERATE lamp 11 lights.