TM 32-5811-025-14&P
6-8. Disassembly/Assembly Procedures.
The following paragraphs provide step-by-step instructions for disassembling and assembling the RF processor
test set.
a. Disassembly. RF processor test set disassembly consists of removing the blower and front-panel switch.
(1) Blower removal.
(a) Remove top and bottom covers.
(b) Remove heat sink cover (from top side).
(c) Remove and tag blower wires.
(d) Loosen three screws (on bottom side) holding blower until nuts release (on top side). Remove
blower from RF processor test set.
(2) Front-panel switch removal.
(a) Remove top cover.
(b) Remove and tag switch wires.
(c) Loosen ring nut securing switch to front panel.
(d) Remove ring nut and pull switch from rear of front panel.
b. Assembly. RF processor test set assembly consists of installing the blower and front-panel switch.
(1) Blower installation.
(a) Position blower in chassis and install three mounting screws.
(b) Connect tagged blower wires as indicated.
(c) Reinstall top and bottom covers.
(2) Front-panel switch installation.
(a) Position switch to mounting hole and tighten ring nut by hand.
(b) Tighten ring nut with pliers.
(c) Connect tagged wires to switch as indicated.
(d) Reinstall top cover.
6-5