TM 11-6625-333-15
h. Set the function switch to OPERATE to
When the function switch is set to
POWER, ADJUST, or SWR, full trans-
mitter output power is dissipated in the
dummy load of the ME-165/G. Do not
2-4 Operational
Procedures
a p p l y power continuously for longer
than 10 minutes or the unit may be dam-
Since the ME-165/G can be operated in various
aged.
modes, the particular mode of operation and the
average power indications to be observed are as
d. S e t t h e M E - 1 6 5 / G f u n c t i o n s w i t c h t o
follows :
ADJUST.
e. Rotate the ADJUST rotary control to obtain
a. Continuous wave (cw) _ Approximately 200
a full-scale indication.
watts.
NOTE
b. Single sideband (ssb) _ _ Approximately 200
Do not keep the control in the ADJUST
watts.
position any longer than necessary for
Approximately 200
c. Compatible amplitude-
meter adjustment.
modulated (am. )
watts.
f. Set the function switch to SWR.
g. Observe that the proper standing wave ratio
watts.
(fsk)
reflected on the upper scale (green area) of the
e. Voice plus fsk _ _ _ _ _ _ _ _ Approximately 100
meter.
watts.
Change 1