TM 11-6625-333-15
d. Key
the
transmitter.
d. Operate each control on the front panel. All
c o n t r o l s should operate s m o o t h l y with positive
e. Compare the power indications on the AN/
action to indicated positions.
URM-120 and the ME-165/G.
NOTE
5-6. Calibration Procedures
The power indications should agree
within 5 percent.
f. If necessary, adjust resistor R17
until
both
The following procedures apply to
No.
power indications agree (e above).
Order
procured on
models
3219-PP-59,
3241-PP-59,
and
later.
CAUTION
Be extremely careful when adjusting
Resistor R17 and capacitor C3 are used to adjust
resistor R17; dangerous RF voltages
the accuracy of the ME-165/G in power measure-
may be present.
ments. Remove the front panel from the case and
proceed as follows:
g. S e t u p t h e e q u i p m e n t f o r o p e r a t i o n a t
approximately 19 mc.
the RF OUTPUT receptacle and the INPUT
indications
on
the
AN/URM-120
and
the
connector on the ME-165/G.
ME-165/G.
b. Set up the equipment for cw operation at
i. If necessary, adjust capacitor C3 until both
s o m e frequency between 1.5 and 2 megacycles
power indications agree within 5 percent.
(mc).
j. Repeat the procedure outlined in a through i
c. S e t t h e M E - 1 6 5 / G f u n c t i o n s w i t c h t o
above until the power indications are correct at
POWER.