TM 11-6625-2632-14
e.
Install terminal lug and resistor (6) and
c. Place assembled component board assembly
hex nut (5) on connector J1 (4).
(15) into position in detector housing assembly (3) and
f. Untag and resolder three wires to connector J1
tighten two screws (11).
(4).
d. Untag and resolder wire from component board
assembly (15) to filter capacitor FL1 (8).
g. Place cover (2) on detector housing assembly
(3). Install four screws (1) through cover.
5-15.
Detector Housing Assembly Installation
5-16.
Panel Assembly Installation
a. Place detector housing assembly (3) on panel
(10).
a.Place panel assembly (7) in position in case (6) and
install two screws (2).
b. Insert two screws (9) through panel (10) and
b. Place cover assembly (4) in position and install
tighten.
two screws (3).
c.Untag and resolder wires to terminal lug (7) and filter
capacitor FL1 (8).
c. Fit neoprene gasket (5) down carefully over
edge of case (6).
d. Place connector J1 (4) in position through panel
(10) into detector housing assembly (3).
d. Close cover assembly (4) down over neoprene
gasket (5) and fasten elbow catch (1).
5-17. Testing
correctly adjusted and the test set meter has been
properly calibrated.
After repair or replacement of components, perform the
5-18. Calibration
Test Set AN/PRM-32 is functioning properly. However,
the performance of the test set may be considerably less
The adjustment of the receiver wire and the calibration of
than satisfactory unless the receiver wire has been
the test set meter are performed in accordance with TB
750-236.
5-8