Figure 34.1. (Added) Special junction box.
h. Insert the TS-1777/VRM-l test probe tip
f. Connect the dc leads of the ME-26A/U to
terminals A (ground) and J (B+) of the 18-
in test jack A. The GREEN indicator must light.
terminal female connector of the CX-7899/VRM-
65. Output Tests
1. The voltage must be between 21 and 22 volts
(fig. 34.4)
dc.
a. Leave the TS-1777/VRM-l ON-OFF switch
Note. For the remaining tests, l djust the model 3206
in the ON position, and the selector switch at A.
power supply form output between +23.4 and +28.6 volts
b. Adjust the output of the PP-3514/U to 0
dc.
volt dc.
g. Connect the AN/USM-98 positive lead to
c. Through the special junction box, connect
TS-1777/VRM-l test jack A, and the negative
the output of the PP-3514/U to the TS-1777/
lead to the probe ground connector. The voltage
VRM-1 probe assembly, and connect the AN/
indicated must be between 15.2 and 16.8 volts dc.
4